5. Move RUN-OFF-START switch
to RUN as soon as HEATER
light comes on. Do not stop in
OFF position.
6.
7.
Move RUN-OFF-START switch
to START for 4 minutes. If
HEATER light does not come on,
move RUN-OFF-START switch
to OFF. Wait at least
15 minutes. Move
RUN-OFF-START switch to
START for 4 minutes. If heater
fails to start after second try,
troubleshoot heater (page 3-14).
Move RUN-OFF-START switch
to RUN as soon as HEATER
light comes on. Do not stop in
OFF position.
NOTE
Personnel heater always starts
at low heat. It changes to high
heat if HI-LO switch is set at HI.
NOTE
If you operate heater for an
extended time, start engine to
keep
batteries
charged
(page 2-161).
TURN PERSONNEL HEATER
OFF
NOTE
When personnel heater is turned
off, blower will run until
Personnel heater cools off.
HEATER light will go off when
personnel heater cools off.
Driver should stay in carrier
until blower stops.
1. Move RUN-OFF-START switch
to OFF.
2. Let personnel heater purge itself.
8. Move HI-LO switch to HI or
LO.
END OF TASK