TM 9-2350-247-34
INSTALL TURN SIGNAL KIT Continued
0076 00
9.
Install clamp (1), lock washer (2), washer (3) and screw (4) on weld nut (5) (M548A3).
10. Secure flasher wiring harness lead (6) with two straps (7).
11. Remove connector (8) from light selector switch (9) on back of instrument panel (10).
12. Separate connector (8). Unsolder main wiring harness circuit 22 lead (11) from pin C in connector. Pull lead from
bushing (12).