TM 9-2350-247-34
REPAIR MULTIPIN CONNECTORS Continued
0006 00
INSTALL RECEPTACLE
NOTE
If replacing lead, cut new wire from bulk supply. Measure original length, gauge, and type of
wire.
1.
Strip insulation from leads (3) to uncover just enough wire to fill well in contact (5).
2.
Slide nut (1) over leads (3).
3.
Push leads (3) through grommet (4) and insert new contacts (5).