TM 9-2350-247-34REPAIR MULTIPIN CONNECTORS — Continued 0006 00REMOVALNOTEUse same procedure for repairing single or multiple lead, and male or female receptacle.1. Loosen nut (1) from receptacle (2). Slide nut back on leads (3).2. Remove nut grommet (4) with contacts (5) from rear of receptacle (2).3. Push leads (3) into grommet (4) until contacts (5) are fully exposed on other side of grommet. Clip or desolder leadsfrom contacts. Discard contacts.4. Remove grommet (4) and nut (1) from leads (3).0006 00-2