TM 9-2350-247-34ADJUST WINCH POWER TAKEOFF (M548A1) — Continued 0045 005. Remove eight screws (1), lock washers (2), bearing cap (3) bearing cap (4), gasket (5), and gasket (6) from PTOhousing (7). Discard lock washers.NOTEBearing cap gaskets are available in 0.010 and 0.020 inch (.25 and .51 mm) thicknesses.6. Match and install gasket (5) and gasket (6) of equal thickness, bearing cap (4) and bearing cap (3), eight new lockwashers (2), and screws (1) on PTO housing (7).7. Repeat Step 5 and Step 6 until drive shaft (8) rotates freely without end play, adding or removing gaskets as required.FOLLOW-THROUGH STEPS1. Install winch power takeoff on carrier (see your -20).END OF TASK0045 00-2