TM 9-2350-247-20-2
REPLACE DIFFERENTIAL OIL PUMP (M548A1) -- Continued
0336 00
REMOVAL
NOTE
If material handling kit is installed, remove bulkhead protector (WP 0487 00).
1.
Disconnect inlet hose (1) and outlet hose (2) from pump (3).
2.
Remove two screws (4) and key washers (5). Remove cover (6) with spacer from transfer gearcase (7). Discard key
washers.
3.
Remove cotter pin (8), slotted nut (9), and washer (10) from pump (3). Discard cotter pin.
4.
Remove two screws (11) and key washers (12). Remove pump (3) and gasket (13) from transfer gearcase (7). Discard
key washers and gasket.
5.
Remove pump drive key (14) and retaining ring (15) from shaft of pump (3). Discard retaining ring.