TM 9-2350-247-20-2
REPLACE BATTERY TO REGULATOR CABLE JACK (M548A3) -- Continued
0299 00
3.
Disconnect battery to regulator plug (1) from battery to regulator cable jack (2) on inside of battery box bulkhead (3).
4.
Remove circuit leads 2 (4) and 2A (5) from inside battery box.
5.
Disconnect generator to regulator harness connector (6) from battery to regulator cable jack (2) on battery box
bulkhead (3).
6.
Remove four screws (7) and lock nuts (8) from battery to regulator cable jack (2) and remove jack from battery box
bulkhead (3). Discard lock nuts.
0299 00-3