TM 9-2350-247-20-2
REPLACE POWER PLANT WIRING HARNESS (M548A3) -- Continued
0298 00
INSTALLATION
1.
Arrange power plant wiring harness on power plant with branches and connectors arranged near mating receptacles.
2.
Connect circuit 406, 406A connector (1) to air heater box receptacle (2).
3.
Connect circuit 33 connector (3) to engine coolant temperature transmitter receptacle (4).
4.
Connect circuit 327 connector (5) to transmission high oil temperature switch receptacle (6).
5.
Connect circuit 1A, 1B connector (7) to fuel pressure switch receptacle (8).
6.
Connect circuit 34 connector (9) to transmission low oil pressure switch receptacle (10).
7.
Connect circuit 74A lead (11) to start relay terminal X2 (12). Secure with nut (13).