TM 9-2350-247-20-2
REPLACE FAN DRIVE BELT IDLER PULLEY (M548A1) -- Continued
0228 00
INSTALLATION
NOTE
Front and rear idler pulleys are installed the same way.
1.
Install one spacer (1) and two bearings (2) in idler pulley (3). Secure with two retainer rings (4).
2.
Install screw (5) through idler pulley (3), support arm (6), and rod end (7).
3.
Install washer (8) and new lock nut (9) on screw (5). Tighten nut to 50-55 lb-ft (68-75 Nm) torque.
FOLLOW-THROUGH STEPS
1.
2.
Start engine (see your -10).
3.
Check fan drive belt idler pulley for proper installation.
4.
Stop engine (see your -10).
5.
Lower center seat (see your -10).
6.
Install power plant rear access door (see your -10).
END OF TASK