TM 9-2350-247-20-2
SERVICE PERSONNEL HEATER FUEL PUMP/ELECTRIC FUEL PUMPS FLOW TEST --
0148 00
Continued
DISASSEMBLY
NOTE
There are two types of fuel pump. For BENDIX/FACET type, do Assembly Step 1, Cleaning
Step 1, and Disassembly Step 2. For WALBRO type, do Assembly Step 2, Cleaning Step 1, and
Disassembly Step 1.
1.
Remove cover (1) , gasket (2) , and strainer element (3) from fuel pump housing (4) . Discard gasket.
2.
Remove three screws (5) , cover (6) , gasket (7) , and filter element (8) from fuel pump housing (9) . Discard gasket.
CLEANING
1.
Clean element with cleaning compound.
ASSEMBLY
1.
Install clean filter element (8) , new gasket (7) , and cover (6) on pump housing (9) . Secure with three screws (5) .
2.
Install clean strainer element (3) , new gasket (2) , and cover (1) on pump housing (4) .