49
Semi-
Annual
(M548A3)
Power Plant
Mount
a. Check mounts and screws for looseness.
Tighten loose screws to 100120
lb-ft (136163 Nm) torque.
Loose or
broken mounts
or screws.
50
Semi-
Annual
(M548A3)
Transmission
Breather
a. Remove transmission breather and check for
cracks, dents, and stripped threads. Replace
damaged breather (WP 0320 00) (WP 0321 00).
Breather
broken or
missing.
b. Clean transmission breather with cleaning
compound. Dry breather and install on
transmission.
Breather
broken or
missing.