Google+
Facebook
LinkedIn
Twitter
Digg
StumbleUpon
Home
Download PDF
Order CD-ROM
Order in Print
Table 16. Semi-Annual Unit Level Preventive Maintenance Checks and Services for M548A1 and M548A3 CONT. - TM-9-2350-247-20-1_650
Table 16. Semi-Annual Unit Level Preventive Maintenance Checks and Services for M548A1 and M548A3 CONT. - TM-9-2350-247-20-1_652
TM-9-2350-247-20-1 Crane (CAB) Components Recovery Vehicle Full Tracked: light Armored M578 (2360-00-439-6242) (EIC:3LA) Manual
Page Navigation
541
542
543
544
545
546
547
548
549
550
551
TM 9-2350-247-20-1
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS — Continued
0128 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
C
REWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
46
Semi-
Annual
Drive Shaft
a. Check for loose screws on 7C universal joints.
Tighten loose screws to 86–94 lb-ft (117–127
N•m)
torque
(M548A3) and 35–40 lb-ft (47–54
N•m)
torque
(M548A1). Loosen and retighten
screws to the above torque value.
M548A3
7C UNIVERSAL
JOINT
M548A3
SCREWS
SCREW
SCREW
7C UNIVERSAL
JOINT
M548A1
7C UNIVERSAL
JOINT
SCREWS
7C UNIVERSAL
JOINT
SCREWS
M548A1
0128
00-61
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business