TM 9-2350-247-20-1INTRODUCTION STE/ICE–R (SIMPLIFIED TEST EQUIPMENT FOR INTERNALCOMBUSTION ENGINES-REPROGRAMMABLE) PROCEDURES—Continued0107 00E001A test number which does not exist has been entered on the TEST SELECTswitches.E002The required transducer is not connected.E003Test number wrong for DCA connected. This can occur if test selected does notapply to the class of vehicle/equipment under test or if the DCA harness does nothave the required transducer.E004No longer used. If message appears turn in test set.E005Required offset test was not performed.E007The VID number and number-of-cylinders information entered do not agree.E008VTM is not receiving required voltage signal for selected test. This message canoccur on tests, 14, 15, and 72 thru 79.E009VTM is not receiving engine speed signal. This applies only to engine power testand SI full power simulation.E010A wrong VID number was entered. The VTM will only accept numbers between 01and 99. If E010 is displayed when the VID entered was between 01 and 99, itmeans that the VID does not agree with the identity of the DCA harness poweringthe VTM. The VTM will accept this, allowing you to power through the DCA whiletesting another vehicle.E011Throttle control was operated incorrectly. It was taking too long to accelerate ordecelerate during power test.E012The SI ignition adapter, TK item 30, or CI pulse tachometer, TK item 34, is missingor is not connected to the VTM.E013VTM is unable to use data received.E014The wrong number of cylinders was entered.E015No longer used. If message appears, turn in test set.E017VTM is not receiving ignition information during dwell test.E018Test discontinued due to no information being detected by VTM. This will occurafter several minutes of no-signal operation.E020No first peak information was detected by the VTM.E021VTM cannot calculate result. Current is over current probe’s range, and VTM didnot sample correct portion of data.E022External voltage was detected in the circuit under test while measuring resistance.E023VTM’s constant voltage source is not working.E024Test is not valid for VID entered.E027Error is entry of compression unbalance constants.E028Test just entered cannot be used with control function 06.E030VID entered conflicts with speed transducer attached.E032Carrier’s cranking speed is varying too much for a compression unbalancemeasurement.0107 00-9
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business