TM 9-2350-247-20-1TACHOMETER MALFUNCTIONS 0088 00INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0541 00, Item 57)Materials/PartsGrease WP 0542 00, Item 14Personnel RequiredUnit MechanicHelper (H)ReferencesSee your -10See your PMCSEquipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Power plant rear access door/panel removed(see your -10)Instrument panel partially removed (WP 0256 00)NOTEM548A1 and M548A3 troubleshooting procedures are the same. M548A1 procedure is shown.T1. Start engine (see your -10).2. Does tachometer fail to show any reading?YESNOGO TO BY (PAGE 0088 00-2)Y1. Stop engine (see your -10).2. Remove tachometer cable (1) from tachometer (2).3. Start engine (see your -10).4. Observe tachometer cable drive tip (3).5. Does tachometer cable drive tip fail to rotate?YESNOYN1. Stop engine (see your -10).2. Replace tachometer (WP 0519 00).3. Verify no faults found.0088 00-1