TM 9-2350-247-20-1ENGINE DOES NOT CRANK (M548A1) 0010 00INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0541 00, Item 57)STE/ICE-R Test Set (WP 0541 00, Item 6)Multimeter (WP 0541 00, Item 29)Socket Wrench Set (WP 0541 00, Item 64)Personnel RequiredUnit MechanicHelper (H)ReferencesSee your -10(WP 0112 00)Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Center seat raised (see your -10)TNOTEThere is an early and late model of auxiliary powerreceptacle. Both early and late models are shown.1. Turn MASTER SWITCH ON.2. Remove cover (1) from auxiliary power receptacle (2).3. Measure voltage between positive (+) terminal (3) and negative(-) terminal (4).4. Does multimeter read more than 17 volts?YESNOTN1. Clean, inspect and repair carrierbatteries (WP 0290 00).2. Verify no faults found.0010 00-1