TM 9-2350-287-20-2
17-20. HYDRAULIC RESERVOIR REPAIR (continued).
9.
10.
11.
12.
13.
Remove six screws (49) and washers (48),
transmitter (16), and gasket (47) from reservoir
(5). Discard gasket.
Remove five screws (50) and Iockwashers (51),
housing assembly (17), and gasket (52) from
reservoir (5). Discard lockwashers and gasket.
Remove elbow (21), reducer (46), ball valve (1),
nipple (55), and reducer (54), as an assembly,
from reducer (53).
NOTE
Perform steps 12 and 13 only if elbow,
reducer, or ball valve are damaged
Remove elbow (21), reducer (46), nipple (55)
and reducer (54) from ball valve.
Remove reducer (53) from reservoir (5).
c.
CLEANING AND INSPECTION
WARNING
Drycleaning solvent P-D-680 is toxic and flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near open flame or excessive heat.
CAUTION
To prevent damage to equipment, do not clean rubber or plastic parts with drycleaning
solvent.
1.
Clean all metal parts with drycleaning solvent and rag.
2.
Inspect all parts for cracks or breaks. Replace any damaged parts.
17-53
|