17-20. HYDRAULIC RESERVOIR REPAIR (continued).
d.
1.
2.
3.
4.
5.
6.
7.
ASSEMBLY
NOTE
l Apply Teflon pipe sealant to all
male pipe threads prior to
assembly.
l Perform steps 1 and 2 only if
elbow, reducer, or ball valve were
damaged.
Install reducer (53) in reservoir (5).
Install reducer (54), nipple (55),
reducer (46), and elbow (21) in ball
valve (1).
Install elbow (21), reducer, ball
valve (1), nipple (55), and reducer
(54), as an assembly, in reducer
(53).
Install new gasket (52) and housing
assembly (17) on reservoir (5) with
five new Iockwashers (51) and
screws (50).
Install new gasket (47) and
transmitter (16) on reservoir (5) with
six washers (48) and screws (49).
Install new nipple (45) inside
reservoir (5).
Install fitter (44) on nipple (45).
17-54
TM 9-2350-287-20-2
|