TM 9-2350-277-34
REPAIR POWER CONTROL ENCLOSURE, REAR PANEL (M1068A3 ONLY) Continued
0093 00
25. Secure leads with new straps (17) as required.
26. Install relay K6 (7), two screws (13), new locknuts (4), and four washers (15) on rear panel (16).
27. Install lead 32Q (12), lockwasher (5), and nut (4) on terminal X2 of relay K6 (7).
28. Install lead 44A (11), lockwasher (5), and nut (4) on terminal X1 of relay K6 (7).
29. Install leads 31B and 31C (8), lockwashers (5), and nut (4) on terminal A2 of relay K6 (7).
30. Install lead 31A (6), lockwasher (5), and nut (4) on terminal A1 of relay K6 (7).
31. Close faceplate (3) and install ten screws (1) and new lockwashers (2).
FOLLOW THROUGH STEPS
1.
Install power control enclosure assembly (See your -20).
END OF TASK
0093 00-8