TM 9-2350-277-34
REPLACE/REPAIR INVERTER AND INVERTER HOUSING ASSEMBLY A2 (M1068A3
ONLY) Continued
0094 00
NOTE
Tag leads/cables before removing/disconnecting.
4.
Remove ten screws (1), cable W5 (2), and six leads (3) from terminal block TB2 (4).
5.
Remove two set screws (5), cable W6 (6), and two leads E4 (7) from terminal block TB1 (8).
6.
Remove screw (9), ground lead W632 (10), ground lead W432 (11), and lockwasher (12) from carrier wall. Discard
lockwasher.
7.
Remove screw (9), two ground leads E5 (13), and lockwasher (12) from carrier wall. Discard lockwasher.
8.
Remove three screws (14), locknuts (15), six washers (16), from blackout curtain (17) and inverter housing (18). Discard
locknuts.
9.
Disconnect two cable W15 connectors (19) from inverter IN1 (20) and inverter IN2 (21).
0094 00-3