TM 9-2350-277-34
REPLACE/REPAIR INVERTER AND INVERTER HOUSING ASSEMBLY A2 (M1068A3
ONLY) Continued
0094 00
13. Remove four screws (10), lockwashers (11), and tray (4) from four resilient mounts (12). Discard lockwashers.
14. Remove sixteen screws (13), locknuts (14), thirty-two washers (15), and four straps (16) from tray (4). Discard locknuts.
15. Remove eight locknuts (17), washers (18), screws (19), and four resilient mounts (12), from housing (6). Discard
locknuts.
16. Remove three screws (20), mounting strip (21), inverter housing (6), and retaining strip (22) from sponson.
0094 00-5