TROUBLESHOOTING - Continued
TM 9-2350-267-10
MALFUNCTION
TEST OR inspection
Corrective ACTION
Step 4.
Step 5.
CONVEYOR - Continued
Check chain tension.
Adjust chain tension (p 3-39).
Check hydraulic control panei PRESSURE gage for reading of between 100
28.
29.
and 300 psi.
Notify Organizational Maintenance if pressure is not within range.
CONVEYOR CHAIN MOVES SLOWLY OR ERRATICALLY
Step 1.
Step 2.
step 3.
Step 4.
Check chain tension.
Adjust chain tension (p 3-39).
Check chain alinement.
Reposition chain on sprockets (p 3-38).
Check flow control valve setting.
Turn fiow control valve knob counterclockwise slowly until chain speed is
satisfactory.
Check main hydraulic pressure gage for reading of 100 to 300 psi.
Notify Organizational Maintenance if pressure is not within range.
STACKER
STACKER TRAY WiLL NOT MOVE
Step 1. Check that stacker chain is not jammed, damaged or off a sprocket.
Remove obstruction, place chain around sprocket(s) or repair chain
(p 3-40).
3-15