TM 9-2350-267-10 OPERATING THE APU - Continued Charging Low Batteries with APU 1. 2. 3. NOTE This procedure applies only to vehicles with low-charge batteries. if no gages or lights function on a vehicle when its MASTER switch is ON, batteries are dead. To charge dead  batteries,  see  page  2-125. Before  trying  to  charge  batteries,  do  the  following: a. b. Check  batteries  for  broken  case,  broken  cable,  severe  corrosion  and other damage. Notify Organizational Maintenance if batteries are damaged. Check  electrolyte  level  (TM  9-6140  -200-14).  Notify  Organizational Maintenance if electrolyte is not at proper level. Park your vehicle close enough to supported vehicle so that slave cable can be  interconnected  at  slave  receptacles  of  both  vehicles. With  brake  depressed,  place  shift  lever  (1)  in  N  (neutral)  and  set  parking brake lock handle (2). To avoid personai injury and vehicle damage, turn OFF the MASTER switch and all other electrical switches in both  vehicles. 2-123