OPERATING THE APU - Continued - TM-9-2350-267-10_151
Shutting Down

TM-9-2350-267-10 Carrier Personnel Full Tracked Armored M113A2 2350-01-068-4077 Carrier Command Post Light Tracked M577A2 2350-01-068-4089 Manual
Page Navigation
  133    134    135    136    137  138  139    140    141    142    143  
TM   9-2350-267-10 OPERATING THE APU - Continued 8. Allow APU to warm up for three minutes, then turn APU Generator switch (1) ON. CAUTION When operating the APU at high altitudes and/or high temperatures,  continuous  heavy-load  demands  by  the electrical and hydraulic systems may cause the APU engine to overheat. In these extreme conditions, the APU  GENerator  switch  should  be  turned  OFF  and  hy- draulic  components  shut  down  periodically.  Continue to run APU without load for several minutes before again  operating  generator  and  hydraulic  components. CAUTION If HIGH AIR Temperature lamp (6) lights during opera- tion, turn OFF the FUEL SHUT OFF switch. Allow APU to cool before restarting. Notify Organizational Main- tenance  if  lamp  lights  often. 2-118