TM 9-2350-261-20-1
S U S P E N S I O N L O C K O U T I N D I C A T O R M A L F U N C T I O NS
( M 7 4 1 A 1 O N L Y)
INITIAL SETUP
Tools:
General Mechanics
Digital Multimeter
Jumper Wire
Personnel Required:
Unit Mechanic
References:
See your -10
Tool Kit (Item 30, App D)
(Item 43, App D)
Equipment Conditions:
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
Trim vane lowered (see your -10)
Power plant front access door open
(see your -10)
Drivers power plant access panel removed
(see your -10)
Power plant rear
(see your -10)
access panels removed
1.
2.
3.
Remove SUSPENSION LOCKOUT indicator cover
lens (l), gasket (2), bulb (3) and gasket (4).
Measure resistance between bulb center contact (5)
and bulb base (6).
Does multimeter read 0-5 ohms?
1. Replace SUSPENSION
LOCKOUT indicator bulb
I
(page 11-22).
2. Verify no faults found.
3-164