TM 9-2350-247-20-3REPLACE WINCH POWER TAKEOFF CONTROL (M548A1) 0414 00THIS WORK PACKAGE COVERS:Removal (page 0414 00-1).Cleaning (page 0414 00-2).Installation (page 0414 00-3).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0541 00, Item 57)Socket Wrench Set (WP 0541 00, Item 63)Torque Wrench (WP 0541 00, Item 67)Materials/PartsGAA grease (WP 0542 00, Item 14)GrommetPersonnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Left grille removed (WP 0390 00)Center seat raised (see your -10)Cab center floor plate removed (WP 0394 00)Power plant rear access covers/door removed(see your -10)Battery negative lead disconnected (WP 0292 00)REMOVAL1. Loosen setscrew (1) that secures outer control cable (2) to power takeoff actuating lever (3).2. Remove jam nut (4), nut (5), and bracket (6) that secure outer control cable (2) to screw (7). Pull control cable frombracket.3. Remove screw (8), washer (9), and clamp (10) that secure outer control cable (2) to power plant compartment.0414 00-1