10-3. PERSONNEL AIR DUCT VENTILATING FAN REPAIR (continued).
7.
8.
Remove motor assembly (23) from fan assembly housing (9).
Remove two screws (27), end cover (21), spring tension washer (22), and two washers (26) from motor
assembly (23).
9.
10.
11.
12.
Remove two brush caps (25) and electrical brushes (24) from motor assembly (23).
Remove armature (31) from motor housing (37).
WARNING
Safety goggles should be worn when removing retaining rings. Retaining rings are
under spring tension and can act as projectiles when released. Failure to follow this
warning can result in severe eye injury.
Remove bearing (36), washer (35), retaining ring (30), insulator (34), and washer (32) from armature (31).
Remove bearing (28), washer (29), and retaining ring (33) from armature (31).