TM 9-2350-287-34
10-3. PERSONNEL AIR DUCT VENTILATING FAN REPAIR (continued).
NOTE
To ensure proper installation, make sure electrical leads are tagged.
3.
4.
5.
6.
Remove four nuts (18), Iockwashers (17), and electrical leads (19) from noise filter (5). Discard Iockwashers.
Remove nonelectrical wire (11), four screws (14) and washers (15), ground wire lead (13), and noise filter (5)
from fan assembly housing (9). Discard nonelectrical wire.
Remove nonelectrical wire (11) and four screws (20) and washers (12) from front of fan assembly housing (9).
Discard nonelectrical wire.
Remove grommet (16) from fan assembly housing (9). Feed four electrical leads (19) and ground wire lead
(13) through grommet (16). Discard grommet.
10-9
|