TM 9-2350-287-20-2
19-2. STE/lCE INSTRUMENT SHUNT REPLACEMENT (continued).
5.
Remove two screws (14), Iockwashers (13), and leads 12330348 and 10897992 (23 and 24) from instrument
shunt (9). Discard Iockwashers.
6.
Remove four screws (12), Iockwashers (11), washers (10), and instrument shunt (9) from hull. Discard
Iockwashers.
b.
INSTALLATION
1.
Install STE/ICE instrument shunt (9) on hull with four washers (10), new Iockwashers (11), and screws (12).
2.
Install leads 10897992 and 12330348 (24 and 23) on instrument shunt (9) with two new Iockwashers (13) and
screws (14).
3.
Install two leads BB and BA (22 and 21 ) on instrument shunt (9) with two washers (18), new Iockwashers (19),
and screws (20),
4.
Install two leads 10897992 (17) on instrument shunt (9) with two new Iockwashers (15) and screws (16).
5.
Install terminal (6) on battery post (8), and tighten screw (7) and nut (5).
6.
Install terminal (1) on battery post (4), and tighten screw (3) and nut (2).
FOLLOW-ON MAINTENANCE:
. Close battery access doors (refer to TM 9-2350-287-10).
19-3
|