TM 9-2350-287-20-2
18-21. APU WIRING HARNESS (12329640) REPLACEMENT (continued).
5.
Remove nut (20), Iockwasher (19), washer (18), and lead circuit N (17) from preheat solenoid (16). Discard
Iockwasher.
6.
Remove nut (8), Iockwasher (9), washer (10), and lead circuit 421 (11) at fuel shutoff solenoid (13). Discard
lockwasher.
7.
Remove connector circuit 66 (28) from top right side of starter relay (26).
8.
Remove connector circuit 65 (27) from bottom right side of starter relay (26).
9.
10.
11.
Remove self-locking nut (39), washer (38), and lead 62 (37) from positive terminal B (41) on generator terminal
box (29). Discard self-locking nut.
Remove self-locking nut (36), washer (35), and lead 478A (34) at interpole terminal D (40) on generator
terminal box (29). Discard self-locking nut.
Remove self-locking nut (33), washer (32), and lead 61 (31) from field terminal A (30) on generator terminal
box (29). Discard self-locking nut.
18-53
|