TM 9-2350-287-20-2
18-10. APU AIR CLEANER, INLET AND OUTLET HOSES, AND TUBES REPLACEMENT
(continued).
b.
1.
2.
3.
4.
5.
WARNING
Sealing compounds can burn easily, can give off harmful vapors, and are harmful to
skin and clothing. To avoid injury or death, keep away from open fire and use in well-
ventilated area. if sealing compound gets on skin or clothing, wash immediately with
soap and water.
INSTALLATION
Apply sealing compound to threads of screws (5).
Install two screws (5) and bracket (6) on APU.
Install air cleaner (11) on bracket (6) and tighten clamp (1).
Install two hoses (3 and 8), four clamps (7 and 10), and tube (4) on the APU. Tighten four clamps (7 and 10).
Install two hose clamps (7) and hose (8) to air cleaner (11)
FOLLOW-ON MAINTENANCE:
• Install APU air cleaner filter (refer to TM 9-2350-287-10).
• Install APU plenum (para 18-17).
18-24
|