TM 9-2350-287-20-2
16-6.
PERSONNEL HEATER DUCT REPAIR (continued).
e.
1.
2.
3.
4.
5.
INSTALLATION
NOTE
Splined nuts are force-fit from engine side of bulkhead. If nuts have fallen out or are
damaged, notify Direct Support maintenance.
Position heater duct (5), bracket (4), and duct guard (3) against bulkhead (6) with mounting holes alined with
two splined nuts (7).
Secure heater duct (5), duct guard (3), and bracket (4) to bulkhead (6) with two screws (1) and washers (2).
Secure bottom of bracket (4) to bulkhead (6) with screw (12) and washer (11).
Position bracket (8) on heater duct (5) and against bulkhead (6) with mounting hole alined with splined nut (7).
Secure heater duct (5) and bracket (8) to bulkhead (6) with screw (10) and washer (9).
FOLLOW-ON MAINTENANCE:
l Install personnel heater outlet hose and tee assembly (para 16-5).
l Perform operational check of heating and ventilating system (refer to TM 9-2350-287-10).
l Move left and right projectile rack assemblies to front of vehicle (refer to TM 9-2350-287-10).
16-14
|