TM 9-2350-287-20-2
15-47. COMMANDER'S ACCESS DOOR REPAIR (continued).
NOTE
Prior to installation, record location, quantity, and position of spacer plates,
spacers, flat springs, and washer.
4.
Install tube (2) and washer(s) (9) on access door (1).
5.
Install 12 flat springs (3), guy anchor (6), spacer plate(s) (7), and spacer(s) (8) on tube (2).
6.
Install two new lockwashers (5) and two screws (4) on access door (1).
f.
ADJUSTMENT
1.
Install spacer plates (7) as required to provide 0.016 +0.062-inch clearance between spring ends and guy anchor
(6).
2.
Install spacers (8) as required to provide 0.005 ±0.020-inch clearance between tube end and cover hinge.
3.
Install washers (9) as required to center access cover (1) in cupola body to within ±3/64 inch.
FOLLOW-ON MAINTENANCE:
None
15-119
|