15-43. AFES FlRE EXTINGUISHER BOX ASSEMBLY REPAIR (continued).
6.
7.
d.
1.
2.
3.
4.
5.
6.
7.
WARNING
Adhesives can burn easily, can give off harmful vapors, and are harmful to skin and
clothing. To avoid injury or death, keep away from open fire and use in a well-
ventilated area. if adhesive gets on skin or clothing, wash immediately with soap and
water.
Apply thin coat of adhesive to mounting surfaces of new seal (15) and AFES fire extinguisher box assembly
(4). Allow adhesive to dry for five minutes or until tacky.
Position seal (15) in place on AFES fire extinguisher box assembly (4) and allow adhesive to cure for 30
minutes.
ASSEMBLY
With aid of assistant, position AFES fire extinguisher box assembly door (9) in place on AFES fire extinguisher
box assembly (4).
CAUTION
When installing hinge pins, tap them only lightly to avoid damaging their threads.
Install two hinge pins (14) and washers (12) to bottom part of door hinge in AFES fire extinguisher box
assembly (4) and door (9).
Install four new self-locking nuts (11 ) and washers (12) on upper and lower hinge pins (14).
Open AFES fire extinguisher box assembly door (9).
Install door handle (10), latch plate (8),
washer (7), and nut (6) on AFES fire
extinguisher box assembly door (9).
Tighten nut (6) until latch plate touches
strike.
Install new cotter pin (5) in nut (6).
Close AFES fire extinguisher box
assembly door (9).
15-106
|