TM 9-2350-287-20-2
15-25. LEFT CANISTER DOOR LATCH ASSEMBLY REPLACEMENT (continued).
c.
1.
2.
d.
1.
2.
e.
1.
2.
3.
4.
CLEANING AND INSPECTION
WARNING
Drycleaning solvent P-D-80 is toxic and flammable. Always wear protective goggles and gloves,
and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes, and DO NOT
breathe vapors. DO NOT use near open flame or excessive heat
Clean all parts with drycleaning solvent. Allow to air-dry.
Inspect parts for cracks, bends, or other damage. Replace unserviceable parts.
ASSEMBLY
Install shims (9) and striker (8) on bracket (1O) with two screws (13), new Iockwashers (12), and washers (11).
Install shims (4) and latch assembly (5) on plate (3) with four screws (7) and new Iockwashers (6).
INSTALLATION
Install plate (1) on hull with two screws (2).
Install plate (3) on plate (1) with four screws (14), new Iockwashers (15), and washers (16).
Close Ieft canister door (refer to TM 9-2350-287-10). If striker (8) contacts and locks properly in latch assembly
(5), door is properly adjusted. If striker (8) does not properly contact latch assembly (5), go to step 4.
Remove two screws (13), Iockwashers (12), and washers (11), shims (9), and striker (8) from bracket (10).
Remove or install shims (9) as necessary to achieve positive Iock of striker (8) in latch assembly (5); then install
shims (9) and striker (8) on bracket (10) with two screws (13), Iockwashers (12), and washers (11).
15-58
|