TM 9-2350-287-20-2
15-15. VENTILATION DOOR ASSEMBLY AND DRAIN HOSE REPLACEMENT (continued).
3.
4.
5.
6.
7.
8.
9.
10.
11.
Sealant is toxic.
Prolonged
breathing of vapors from
organic solvents is dangerous.
Rubber gloves should be used.
Wash hands thoroughly with
soap and water before eating,
drinking, or smoking.
Apply a thin layer of rubber adhesive to
seal contact areas of door (21).
Install new seal (24) on door (21).
Install arm (11 ) between hinge lugs (7)
and secure with hinge pin (12).
Install new packing (13) in retainer nut
(14). Install retainer nut (14) on hinge
pin (12).
Close driver’s hatch (5).
Aline holes in mountings lugs (22) on
door (21) with holes in arm (11) and
secure with pin (23), washer (19), and
new cotter pin (20).
Position handle (15) on hinge pin (12)
and aline hole in handle (15) with hole in
hinge pin (12). Secure handle (15) to
hinge pin (12) with new spring pin (16).
Install spring (18) in spring retainer (17).
Install spring (18) and spring retainer
(17) on handle (15) with pin (6) in slots
of spring retainer (1 7).
Position ventilator door grille (3) in place
on top-deck mounting surface (4) and
secure with socket head screw (2) and
five screws (1).
FOLLOW-ON MAINTENANCE:
• None
15-32
|