15-15. VENTILATION DOOR ASSEMBLY AND DRAIN HOSE REPLACEMENT (continued).
3.
4.
5.
6.
7.
8.
9.
10.
b.
1.
2.
Remove cotter pin (20) and washer (19) from ventilation door (21 ) and pin (23). Discard cotter pin.
Remove pin (23) and arm (11) from mounting lugs (22) on door (21). Remove door (21).
Handle assembly is spring loaded. To avoid injury to personnel, extreme care should
be taken when removing spring pin.
Remove spring pin (16) from handle (15). Discard spring pin.
Raise handle (15) to relieve tension on spring (18) and hinge pin (12). Remove handle (15) from hinge pin
(12), spring (18), spring retainer (17), and pin (6).
Remove retainer nut (14) and packing (13) from hinge pin (12). Discard packing.
Remove hinge pin (12) and arm (11) from hinge lugs (7).
Remove seal (24) from door (21). Discard seal.
Loosen two clamps (9) and remove hose (10) from tube (8).
INSTALLATION
Install two clamps (9) on hose (10). Position
hose (10) in place on tube (8) and secure
with two clamps (9).
WARNING
Drycleaning solvent P-
D-680 is toxic and
flammable. Always wear
protective goggles and
gloves, and use only in a
well-ventilated area.
Avoid contact with skin,
eyes, and clothes, and
DO NOT breathe vapors.
DO NOT use near open
flame or excessive heat
Clean seal contact areas of door (2
drycleaning solvent.
15-31
|