TM 9-2350-287-20-17-71. APU CONTROL BOX TO APU VOLTAGE REGULATOR CABLE ASSEMBLY (12330248)REPAIR (continued).7.Disconnect APU power feed plug (22) from harness 12330257 receptacle (23).8.Disconnect APU fuel pump connectors (24 and 26) from APU fuel pump leads (25).9.10.Remove screw (27), Iockwasher (28), washer (29) and retaining strap (30) from vehicle. Discard Iockwashers.NOTEDo not remove other harness from strap assemblies.Remove screw (18), Iockwasher (19), washer (20) and harness from each of three strap assemblies (21).Discard Iockwashers.7-216