8.
9.
10.
11.
12.
13.
Disconnect electrical connector (14) from bilge pump relay (15).
Maneuver electrical wiring clear of voltage regulator (7).
Remove two screws (16), three Iockwashers (17), and three electrical leads (18) from circuit breaker (19).
Discard Iockwashers.
Remove nut (26), screw (30), washer
(29), Iockwasher (27), and strap (28)
from mounting bracket (25). Discard
Iockwasher.
Remove screw (37), washer (36),
Iockwasher (35), and three ground leads
(34) from mounting bracket (25). Discard
Iockwasher.
Remove screw (22), washer (23),
lockwasher (32), nut (31), and two ground
leads (33) from voltage regulator
mounting bracket (24). Discard
Iockwasher.
Remove four nuts (38), screws (21 ),
washers (20), Iockwashers (39), and
mounting bracket (25), voltage regulator
(7), starter relay (8), bilge pump relay
(15), and circuit breaker (19) as an
assembly from support assembly (40).
Discard Iockwashers.