TM 9-2350-287-20-12-22. SIMPLIFIED TEST EQUIPMENT FOR INTERNAL COMBUSTIONENGINES (STE/lCE) (continued).a. STE/lCE PMCS - (continued).(3) CURRENT FIRST PEAK TEST - DCA.A. 1. Turn MASTER switch to OFF (refer to TM 9-2350-287-10).2. Dial 72 into TEST SELECT.3. Press and hold TEST button until the mes-sage ‘CAL” appears on the display, then re-lease.4. Wait for offset value to appear.Is offset value in the limits of -225 to +225?Go to TM 9-4910-571-12&Pfor offset fault isolationB.1. Press and release TEST button.2. Wait for message “GO" to appear on display.NOTEIf “.9.9.9.9” appears, go toTM 9-4910-571 -12&P for offset fault isolation.3. When “GO” appears on display, pull and holdengine fuel shutoff handle and depress thestarter switch until “OFF or “EO13 is on display.NOTEIf VTM loses power and comes on againshowing”- -- -“ or display after cranking, goto para 2-22.b(4).Is current within 875 to 1680 amps?Got to para 2-22.a(5).Go to para 2-22.b(2).END OF TASK2-392