TM 9-2350-287-20-1
2-22. SIMPLIFIED TEST EQUIPMENT FOR INTERNAL COMBUSTION
ENGINES (STE/lCE) (continued).
a. STE/lCE PMCS - (continued).
(3) CURRENT FIRST PEAK TEST - DCA.
A. 1. Turn MASTER switch to OFF (refer to TM 9-
2350-287-10).
2. Dial 72 into TEST SELECT.
3. Press and hold TEST button until the mes-
sage CAL appears on the display, then re-
lease.
4. Wait for offset value to appear.
Is offset value in the limits of -225 to +225?
Go to TM 9-4910-571-12&P
for offset fault isolation
B.
1. Press and release TEST button.
2. Wait for message GO" to appear on display.
NOTE
If .9.9.9.9 appears, go toTM 9-4910-571 -
12&P for offset fault isolation.
3. When GO appears on display, pull and hold
engine fuel shutoff handle and depress the
starter switch until OFF or EO13 is on display.
NOTE
If VTM loses power and comes on again
showing- -- - or display after cranking, go
to para 2-22.b(4).
Is current within 875 to 1680 amps?
Got to para 2-22.a(5).
Go to para 2-22.b(2).
END OF TASK
2-392