TM 9-2350-287-20-12-19. TROUBLESHOOTING CHART (continued).v. AFES, ENGINE (continued).(6) BOTTLES NOT DISCHARGING WHEN PULLINGMANUAL CABLES.Initial Setup:Tools/Test Equipment:l Engine AFES Test/Alarm panel MAINT switch inl General mechanic’s tool kit (Item 24,maintenance position (para 21-2).Appendix I)Equipment Conditions:l Left and right projectile rack assemblies movedto rear of vehicle (refer to TM 9-2350-287-10).NOTEl Instead of using multi meterfor voltage check, STE/lCEtroubleshooting,INDIVIDUALBATTERY VOLTAGE TEST-TEST89 maybe performed.l Instead of using multi meterfor continuity check, STE/lCEtroubleshooting, TEST 91 may beperformed.A. Ensure locking pin on engine fire extin-guisher no. 2 is in the stowed position.Check adjustments of cables(para 21-16).END OF TASK2-336