TM 9-2350-287-20-12-19. TROUBLESHOOTING CHART (continued).u. AUXILIARY POWER UNIT (continued).(2) ENGINE FAILS TO CRANK. All other electricalsystems operate (continued).Repair wire 65 or replace harness 12330248(para 7-71). Verify problem is solved.l. 1. Remove and disassemble APU controlbox (para 7-22).2. Place multimeter red probe on pin D andblack probe in lead 65 connector.3. Check for continuity.Repair wire 65A or replace harness 12330248(para 7-71). Verify problem is solved.J. 1. Check APU control box APU START switchfor continuity.2. Place multimeter probes on each connectorof APU START switch.3. Hold APU START switch in ON position(refer to TM 9-2350-287-10).4. Check for continuity.Replace APU START switch (para 7-22).Verify problem is solved.K. 1. Check PREHEAT switch for continuity.2. Place multimeter probes on each connectorof PREHEAT switch.3. Place PREHEAT switch in ON position (referto TM 9-2350-287-10).4. Check for continuity.Continued on next page2-307