TM 9-2350-287-20-12-19. TROUBLESHOOTING CHART (continued).g. GAGES (continued).(9) TACHOMETER FAILS TO OPERATE WHENENGINE IS RUNNING (continued).Replace tachometer (para 7-9). Verifyproblem is solved.WARNINGB.A protective fan screen must beinstalled prior to doing main-tenance in the engine compartment,when the engine is running orengine is in ground hop mode.Contact with a rotating fan cancause injury.1. Reconnect tachometer drive shaft to ta-chometer.2. Install protective fan screens (para 2-8).3. Disconnect tachometer drive shaft from ta-chometer drive on engine.4. Have assistant hold fuel shutoff out andcrank engine (refer to TM 9-2350-287-10).5. Observe tachometer drive for rotation.Does tachometer drive rotate?GO TO STEP EC. 1. Connect tachometer drive shaft to tachom-eter drive on engine.2. Disconnect tachometer drive shaft from bulk-head coupling.Continued on next page2-129