TM 9-2350-287-10HYDRAULIC RESERVOIR: Holds hydraulic system fluid. Reservoir capacity is 13 gallons (49.26 liters).SUCTION LINE: Passes fluid to the main or backup hydraulic pump. A strainer at the inlet of the line preventscontaminants from entering the hydraulic circuits.BALL VALVE: Controls the flow of hydraulic fluid through the suction line. This valve is manually operated and must beopened before main or backup pump is operated.RETURN LINE: Passes exhausted hydraulic fluid back to the reservoir. An in-line, 1 O0-micron filter removes particlesfrom the returning fluid.BREATHER CAP: Vents reservoir pressure to atmosphere.FILLER CAP AND TUBE: Permit ease of hydraulic fluid refill. A strainer is housed within the tube to prevent entry ofcontaminants.FLUID LEVEL TRANSMITTER: Monitors the level of hydraulic fluid in the reservoir. The transmitter emits an electronicsignal to a level gage on the hydraulic control panel.FLUID TEMPERATURE TRANSMITTER: Monitors the temperature of hydraulic fluid in the reservoir. The transmitteremits an electronic signal to a temperature gage on the hydraulic control panel.MICRON FILTER: Filters hydraulic fluid returning to the reservoir.1-13
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business