TM 9-2350-287-10EMERGENCY PROCEDURES (continued)ConveyorHydraulic Failure.If conveyor motor or hydraulic system fails, conveyor may be operatedaccording to the procedures below.maintenance.Report conveyor motor or hydraulic system failure to Unit1.Check for broken chain. If chain is broken, repair (p. 3-42) and retry conveyor operationhydraulically.2.If chain is not broken, insert manual handcrank (1) into socket at inboard end of conveyor.3.Turn handle clockwise to move chain out, counterclockwise to move chain in.4.If chain does not move properly, troubleshoot conveyor (pp. 3-13 and 3-14).2-234