TM 9-2350-287-10
Table 2-1. Preventive Maintenance Checks and Services for Model M992A1
Location
Item Interval
Crewmember
Not Fully Mission
No.
Item to
Procedure
Capable If:
Check/
Service
50 Weekly Batteries
(continued)
b. Make sure the vent holes on caps
are open to permit escape of gases;
also, make sure caps are screwed
on tightly.
c. Inspect terminals, posts, clamps,
cables, battery hold-downs, and
battery boxes for corrosion. If
corrosion is present, have Unit
maintenance clean and coat all
clamps, hold-downs, and battery
boxes, except posts and terminals.
CAUTION
To reduce battery damage, do
not remove batteries from
equipment battery boxes,
except during scheduled
maintenance or battery re-
placement. Battery replace-
ment will be performed only by
Unit maintenance personnel.
d. Make sure a light coat of GAA
grease is applied and covers all
terminals and posts after clamping
down battery. Keep grease from
between posts and terminals.
VENTS IN CAP
Change 1
2-71