TM 9-2350-277-34
PATCH PANEL BOX A10 INOPERATIVE (M1068A3 ONLY)—Continued
0010 00
GY
1. Remove cable plugs from the Patch Panel Box A10 jacks as
follows:
Cable W111 plug P1 (1) from J125 (5)
Cable W112 plug P1 (2) from J124 (8)
Cable W113 plug P1 (3) from J123 (7)
Cable W114 plug P1 (4) from J126 (6)
2. Measure
resistance
between pins of the following:
J125 (5) to J119 (9)
J126 (6) to J120 (10)
J123 (7) to J121 (11)
J124 (8) to J122 (12)
3. Does
multimeter
read 0 ohms for each measurement?
YES
NO
GYN
1. Repair Patch Panel Box A10
(WP 0099 00).
2. Verify no faults found.
0010 00-14