TM 9-2350-277-34VEHICLE WILL NOT ACCEPT EXTERNAL AC POWER (M1068A3 ONLY)—Continued 0008 008Y1. Install XK2 relay (1) in relay socket (2) and secure with relaybail (3).2. Apply external source of AC power to SICPS vehicle(TM 11-7010-256-12&P).3. Measure voltage between K3 relay terminal A2 (4) and terminalblock E4 post 1 (5).4. Does multimeter read 110 volts AC or for each measurement?YESNO8YN1. Replace K3 relay (WP 0091 00).2. Verify no faults found.0008 00-10