TM 9-2350-277-34
REPLACE FUEL CONTROL VALVE Continued
0078 00
8.
Repeat Steps 1 - 7 with shutoff solenoid side only of fuel control valve energized with 24 V dc.
9.
Calibrated cubic centimeter glass container should now contain 8.5 ± 2 cubic centimeters of fuel.
10. If fuel flow rates are not within limits, adjust flow. Turn adjusting screw to right to increase and to left to decrease.
Adjust high heat flow first, then low heat flow.
11. After fuel flow is adjusted within limits, seal adjusting screw with insulating varnish.
12. If fuel flow cannot be adjusted within limits, replace fuel control valve.
0078 00-4