TM 9-2350-277-34REPLACE FRONT MAIN WIRING HARNESS — Continued 0030 0034. Install circuit 6 (3) and 6A (4) leads into distribution box (6). Secure 6 and 6A leads on bus bar (5) with new lockwasher(2) and screw (1).35. Install circuits 2 (14), and 2A (20) leads into master switch panel (10) through distribution box (11). Secure circuit 6(15), 2 (14) and 400 (16) on conductor bus (17) with new locknut (12), and screw (13). Secure circuit 2A (20) lead onconductor bus (17) with lockwasher (19) and nut (18).0030 00-30