TM 9-2350-277-20-6REPAIR POWER CONTROL ENCLOSURE FACEPLATE AND BRACKET (M1068A3 ONLY)— Continued0828 0020. Install cascade remote harness RP1 (1) on faceplate (2) and two inverters. Secure with four screws (3) and newlocknuts (4).21. Install circuit breaker CB2 (5), four screws (6), and new lockwashers (7) on faceplate (2).22. Install circuit 36C lead (8), nut (9), lockwasher (10) on terminal 2 of circuit breaker CB2 (5).23. Install circuit 31B lead (11), lockwasher (10), and nut (9) on terminal 1 of circuit breaker CB2 (5).24. Install circuit breaker CB1 (12), two screws (13), and new lockwashers (14) on faceplate (2).25. Install circuits 9A, 9E, and 9D leads (15), lockwasher (16), and nut (17) on terminal 2 of circuit breaker CB1 (12).26. Install circuit 7A lead (18), lockwasher (16), and nut (17) on terminal 1 of circuit breaker CB1 (12).27. Apply primer and sealing compound to threads of terminal 1 of circuit breaker CB1 (12).28. Install safety cover (19) and nut (20) on terminal 2 of circuit breaker CB1 (12). Wrap velcro strap (21) aroundlocal wiring.0828 00-10
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business